HIT balcony connection system
Text size: A A A
Skip Navigation Links Back Home | Products | Concrete reinforcement products | HIT balcony connection system

Halfen - HIT balcony connection system


Balcony with HIT element


  • Design evolved after careful analysis of all aspects of the detail
  • Hairline cracks due to thermal movement avoided
  • Easy to work with: site problems avoided
  • Definite thermal separation between floor slab and balcony
  • Dew point avoided
  • Reduces heating costs and CO² emissions
  • Reduces the lifetime cost of the building
  • Assists in complying with Part L


Introduction

With improved insulation standards over the last 30 years, and with energy efficiency becoming an ever more important design consideration, Halfens HIT can provide a solution to the architectural and engineering problem of creating a thermal break whilst still providing a structural connection.

Whilst thermal breaks are particularly important for balcony slabs as shown below, HIT can also be used to provide thermal breaks for a wide variety of structural connections - some of which are illustrated in the following pages.

The HIT among balcony slab connections


  • Dew point avoided
  • Design evolved after careful analysis of all aspects of the detail
  • State of art insulated thermal connections
  • Provides a thermal break and structural connection for a wide variety of applications
  • Standard metre elements and 200 mm make up pieces
  • Economic design and use of material, minimal site wastage
  • Also available in a fire resistant design (up to 90 minutes)
  • Officially approved by the German Construction Supervisory Board DIBt
  • Approval Number Z-15.7-171
  • Thickness of insulation is 80mm
  • Minimum slab depth 160mm
  • Standard units up to 250mm deep (larger depths can be designed & manufactured to order)


Economical

Standard metre elements, 200mm make-up pieces and 50mm in-fill pieces can be combined to form any length. The optimum cut to size layout can be achieved giving economy of materials. Halfen can assist in the layout if required.

Easy to install

Simply place the HIT unit on formwork, fix reinforcement and pour concrete. The HIT insulation provides the shuttering for the concrete

Minimises slab depth

Suitable for flat slabs because HIT is installed within the depth of the slab, therefore no increase in storey height due to insulation build up.

Product Sales & Support


reinforcement@halfen.co.uk
+44 (0)1582 470 365



Case Studies


Richmond Gate, Bournemouth
View case study
Festival Park - Glasgow
View case study
Downloads


Brochures

CAD


web design kent